My Original Wiring SR Wiring After this I worked out all the pins that need to be changed. Which left me with this set of instructions. Take C5 and move to C6 Take B1 and move to C5 Take B2 and move to B1 Remove B5 + B6 and tape them individually. (Unused) Take A10 and move to B5 Take A11 and move to B6 Take A8 and move to B2 Take A9 and move to A8 This is the full list of instructions, and everything worked sound. If B5+B6 are not taped up individually (touching) it will earth the temperature and spike the gauge. Here are my original wiring pictures: Module A Module B Module C If your original wiring is identical to the above, the instructions will work 100%. If not, im not sure, but i may be able to help so just ask. Hopefully this helps someone Thanks, Chris